What is a Boiler Economizer? Discussion and Resolution Strategies for Frequent Economizer Leakage Problems

The Economizer, named for its function of saving coal (energy), is a device installed in the lower section of the boiler tail flue to recover and utilize waste heat.

It heats the boiler feedwater to saturated water at drum pressure, thereby improving thermal efficiency and saving energy. Its name derives from its ability to lower the exhaust gas temperature of the flue gases.

Steel Tube Economizers are not restricted by pressure and can be designed as boiling types. They are typically constructed from carbon steel tubes with outer diameters ranging from 32 to 51 mm. To enhance heat transfer, fins and ribs may be added to the outside of the tubes. This type of economizer consists of parallel, horizontally arranged serpentine tubes.

Economizers are most widely used in industrial settings but have become increasingly common in agricultural and related commercial fields in recent years.

Economizers can be classified in several ways:

  1. Based on Feedwater Heating Degree: Non-boiling type and Boiling type.
  2. Based on Material: Cast iron and Steel tube types. Non-boiling economizers are usually made of cast iron, though exceptions exist (some models may use steel tubes). Boiling economizers must be made of steel tubes. Cast iron economizers are suitable for boilers with pressures not exceeding 2.5 MPa; above this pressure, steel tube economizers should be used.
  3. Based on Installation Orientation: Vertical type and Horizontal type.
  4. Based on Relative Flow Direction of Flue Gas and Feedwater: Parallel flow, Counter flow, and Mixed flow types.
  5. Based on Structural Form: Bare tube economizers and Finned tube economizers. The latter can be further divided into H-type finned economizers and Spiral finned economizers.
  6. Based on Heat Transfer Mode: Direct conduction and Indirect conduction. Direct conduction uses boiler exhaust gas to directly radiate and preheat boiler feedwater. Indirect conduction preheats the water indirectly via a heat transfer medium. In recent years, with technological advancements, especially breakthroughs in aerospace ultra-conductive materials, the application of indirect conduction technology in boiler energy saving has become increasingly widespread.

Functions

The economizer plays a vital role in the boiler system. Its core function is to preheat and recover boiler feedwater, thereby improving boiler efficiency and reducing energy consumption. Additionally, the economizer can help reduce harmful emissions in the boiler flue gas to some extent, contributing to both environmental protection and energy saving goals.

  1. By absorbing heat from the low-temperature flue gas, the economizer lowers the exhaust gas temperature, reducing exhaust heat loss and saving fuel.
  2. Heating the feedwater in the economizer before it enters the drum reduces the heat absorption required by the heating surfaces. Therefore, the economizer can partially replace the more expensive evaporative heating surfaces, achieving energy savings.
  3. Raising the feedwater temperature reduces the temperature difference between the feedwater and the drum wall upon entry, thereby lowering thermal stress and extending the drum’s service life.

Energy Saving Principle

By adding a regenerative process to the cycle, the average temperature of heat absorption is increased, thereby enhancing the cycle efficiency.

During the startup phase of a boiler (especially a drum boiler), the water-steam circuit circulation is not yet established, and boiler feedwater is stagnant. At this point, the water inside the economizer is also static. As boiler firing intensifies and flue gas temperature rises, the water in the economizer is prone to vaporization, causing local overheating. To prevent this, a recirculation line is typically installed, connecting from the drum’s downcomer to the economizer inlet. This ensures water flows through the economizer, preventing vaporization.

Discussion on Economizer Leakage Prevention Methods

Water Feeding Strategy After Boiler Ignition

After boiler ignition, water feeding control usually adopts two methods: no feeding and intermittent feeding. If no water is fed at all, a large amount of steam can accumulate within the economizer, potentially causing local overheating. In the case of intermittent feeding, temperature fluctuations within the economizer pose a potential threat to metal welds. To mitigate these risks, a common practice is to use a feedwater bypass to uniformly introduce steam, ensuring dynamic evaporation within the economizer and reducing leakage risk.

Control of Temperature and Feedwater Flow

During boiler operation, stable control of water quantity and temperature is crucial for the normal operation of the economizer. Particular vigilance is needed against sudden decreases or increases in feedwater flow, as both can cause economizer overheating and lead to leakage.

Monitoring and Handling of Flue Gas Temperature Deviation

During actual boiler operation, it is necessary to constantly monitor whether there is a temperature deviation between the flue gases on both sides of the economizer. If a deviation is detected, the cause must be quickly identified and corrective measures taken. Often, such deviations are caused by economizer leakage, necessitating immediate boiler shutdown for repair to prevent damage to other tubes.

Preventing Oxygen Corrosion of Economizer Tubes

To ensure long-term stable operation of the economizer, preventing oxygen corrosion of the tubes is essential. This requires monitoring not only that the deaerator temperature and pressure meet standards during operation, but also ensuring that the vent valve is normally open and its temperature is normal.

Measures Against Fly Ash Erosion

Fly ash erosion is another major hazard during economizer operation. To prevent pipe erosion by fly ash, the following measures can be taken:

High Wear Areas of Economizers

Certain parts of the economizer are particularly susceptible to severe wear from fly ash during operation. These include:

  1. Where flue gas turns from the horizontal pass into the vertical pass: Centrifugal force throws most ash particles towards the rear wall, increasing fly ash concentration there.
  2. Areas near the walls: Gaps between the tubes closest to the walls and the wall itself, or gaps between tube rows forming “gas lanes” or “bypass lanes”. Due to significantly increased flow velocity (proven to reach 12-15 m/s, 3-4 times the velocity within the tube bank), tubes or bends in these lanes experience wear rates potentially tens of times higher. Therefore, special attention and effective protective measures are crucial in the design and operation of these high-wear areas.

Protective Measures for Economizers

Protective plates and shields (curtains) are indispensable facilities in the operation and maintenance of economizers. Their design and installation aim to reduce fly ash erosion of economizer tubes, extending their service life. These protective measures also help ensure stable operation of the economizer and improve the overall system efficiency.

Routine Inspection

During routine economizer maintenance, regular inspections should include checking the integrity and tightness of protective plates and shields, and looking for signs of ash accumulation or blockage. These checks ensure these protective facilities remain in good condition and effectively reduce wear.

Cleaning and Maintenance

Ash deposits and blockages on the economizer need periodic cleaning. This maintains unobstructed flow and prevents failure of protective devices due to excessive ash buildup. Regular maintenance of protective plates and shields to ensure their tightness and integrity is also essential.

Repair and Replacement

If severe wear or damage to protective plates or shields is found during routine inspections or cleaning, they should be repaired or replaced promptly. This is vital for ensuring stable economizer operation and system efficiency. Also, ensure newly installed protective devices are properly commissioned and functioning.

Specific Maintenance Tasks:

  • Remove ash deposits from the outer surfaces of tubes.
  • Carefully inspect tubes for wear, deformation, and corrosion; replace unqualified tubes and bends promptly.
  • Conduct a comprehensive overhaul of supports, hangers, tube clamps, and anti-erosion devices.
  • Carefully inspect and adjust the condition of header supports.
  • Open handholes to thoroughly inspect internal corrosion and scaling, and perform cleaning.
  • Perform necessary alignment of tube banks to ensure they are neat and uniform.
  • Measure tube creep expansion to monitor their condition.

Special Overhaul Projects:

  • Professionally treat serpentine tube welds exhibiting numerous defects, or replace tubes exceeding 5% of the total.
  • Acid clean the economizer to remove internal corrosion and scaling.
  • Replace the entire economizer assembly to ensure performance and efficiency.
  • Replace damaged headers to ensure normal system operation.
  • Add or remove economizer heating surface as needed to achieve optimal thermal efficiency.