Economizer Protection Measures During Boiler Start-up and Shutdown​

1. Pre-ignition Preparations and Issues

Before ignition, the boiler is filled with water to the lowest visible level in the water gauge. However, as ignition starts, the furnace water temperature gradually increases, causing its volume to expand and subsequently raising the water level. As the furnace water temperature continues to climb, steam begins to generate within the water walls, further driving a continuous rise in the boiler water level. Therefore, for a considerable period after boiler ignition, no additional water feeding is actually required.

2. Boiler Start-up and Economizer Risks

The primary function of the economizer recirculation valve is to utilize the density difference of the working fluid between the steam drum and the economizer during boiler start-up or shutdown when feedwater is interrupted. By opening the recirculation valve, a natural circulation loop is formed. This circulation continuously replenishes the water in the economizer, ensuring its safe operation. During boiler start-up and shutdown, feedwater is supplied intermittently, causing the water in the economizer to stop flowing. Meanwhile, under the influence of high-temperature flue gas, the water may gradually or completely evaporate. This can lead to overheating of the economizer tubes due to external high temperatures and the absence of internal water cooling, potentially causing damage. Hence, the recirculation valve must be opened during interruptions in water feeding to protect the economizer.

3. Operation of the Recirculation Valve

However, the economizer recirculation valve should be closed during normal boiler operation. During the initial ignition phase or after shutdown, when water feeding is stopped, the water in the economizer also ceases to flow. Yet, the economizer continues to be heated by high-temperature flue gas. Without effective cooling, it risks overheating and damage. Simultaneously, the water inside the economizer may boil, vaporize, or even generate superheated steam. To mitigate these risks, a dedicated recirculation pipe and valve are installed between the economizer inlet and the steam drum. When feedwater is intermittent, the recirculation valve is opened, allowing water from the steam drum to flow through the economizer and back to the drum, forming a natural circulation loop that effectively cools the economizer.

4. Problems Caused by Improper Operation

Conversely, during continuous water feeding, the recirculation valve must be closed to prevent feedwater from short-circuiting directly into the steam drum via the recirculation pipe, which would bypass the economizer and risk its overheating and burnout. If the recirculation valve is inadvertently left open during water feeding, feedwater may enter the steam drum through both the recirculation pipe and the economizer. Since the flow resistance in the economizer is significantly higher than in the recirculation pipe, the water flow through the economizer may be greatly reduced, compromising its protection.

Furthermore, the tightness of the economizer recirculation valve is crucial. If the valve does not close tightly during boiler operation, water that has not been heated by the economizer may flow directly into the steam drum. This water, being much cooler than the saturated water in the drum, can cause thermal stress cracks in the drum metal due to uneven cooling.

5. Economizer Protection Measures

During the transition from start-up to normal operation, forgetting to close the recirculation valve can lead to several issues. Besides potentially causing economizer damage due to insufficient flow, the direct entry of cold feedwater into the steam drum via the recirculation pipe can locally reduce the boiler water temperature, disrupt steam-water separation, and impair steam quality. Additionally, the thermal stress at the interface between the recirculation pipe nozzle and the steam drum increases, which over time could cause circumferential cracks in the drum.

Therefore, it is essential to close the economizer recirculation valve when feedwater is intermittent or during the transition between start-up and normal operation. Moreover, for drum-type boilers operating normally, closing the recirculation valve is necessary because direct feedwater entry into the drum lowers the local water temperature, affects steam-water separation and steam quality, and subjects the metal at the recirculation pipe-drum interface to thermal stress, potentially leading to cracks over prolonged periods.

Furthermore, the economizer recirculation should not be activated after a shutdown caused by an economizer tube leak. In the initial stages after shutdown, the furnace walls remain hot, and there is no water flow in the economizer. Opening recirculation might cause drum water to leak through the damaged economizer. Regulations typically require waiting 24 hours after shutdown and ensuring the water temperature drops below 80°C before draining the boiler. If the water temperature is high, premature draining could cause rapid cooling of convection or water wall tubes (which have thinner walls and lower heat capacity), leading to leaks at drum expansion joints or increased thermal stress at welded joints. To protect the economizer after shutdown, measures such as reducing makeup water flow rate and extending water feeding duration can be adopted.